Of the five controls tested the enclosing hood, the downdraught bench and the on-tip extraction system are the most effective. Each has advantages and disadvantages in various situations and careful consideration of the processes and tasks to be controlled is required to select between the three. The mobile capturing hood is capable of controlling exposure if used correctly, but like all capturing hoods requires repositioning if the source moves in order to keep it within the effective capturing zone. This means that the potential for worker misuse leading to exposure to solder fume is high, for this reason it should be considered secondary to the other forms of control in the opinion of the author.

“Every employer who provides any LEV to meet regulation 7 shall ensure that, it is maintained in an efficient state, in efficient working order, in good repair and in a clean condition – Regulation 9.1 COSHH” Where engineered controls have been used the employer must ensure that they are tested and thoroughly examined with a suitable record kept for minimum of 5 years. Further more the regulation states that: “Any LEV system must be thoroughly appraised and tested at least once every 14 months. – Regulation 9.2. This is reduced to 6 months in certain circumstances.”

As LEV is a control measure under COSHH Regulations it must be regularly and thoroughly inspected and tested. As stated above, LEV regulations outline that any employer who uses local exhaust ventilation to control hazardous substances must ensure that it is operating effectively. Local Exhaust Ventilation Testing is a legal requirement in the UK. All equipment must be thoroughly examined and tested by a competent person at least every 14 months to ensure employees are safe.

Equipment that draws pollutants from an operation or process in the working environment. Made up of an inlet like a hood, slit, arm, cabinet or booth. This will be located near to or close to the area of the substance release. All suchlike equipment needs to be connected by ducting and a fan to enable the movement of air. The removed air passed through a filter or is extracted to atmosphere away from the workplace. How Welding Supplies Direct can help ? WE will carry out a thorough tests in line with COSHH Regulation 9 as detailed in HSE Guide HSG258 Our levels of service can be tailored to your Companies needs. However, most clients choose to take advantage of by combining servicing with the LEV testing. Read extra info at Local Exhaust Ventilation LEV Testing.

Health and Safety ExecutivePage 11 of 111Controlling airborne contaminants at work: A guide to local exhaust ventilation (LEV)Health and Safety Executive?If an employer is using a substance that could form an explosive atmosphere they must consider their responsibilities under the Dangerous Substances and Explosive Atmospheres Regulations 2002 (DSEAR),8 and the supplier of equipment for use in an explosive atmosphere their responsibilities under the Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations 1996.