21 01 24

Cleanroom pharma supplier today: Clean room (aseptic room) should meet the standard requirements: The aseptic room should have good lighting, avoid moisture and stay away from contaminated areas. The area is generally not more than 10㎡, not less than 5㎡and the height shall not exceed 2.4m. It is composed of 1-2 buffer rooms and operation rooms (The doors of the operation room and buffer room should not be directly opposite); Transfer window with sterilizing function between handling room and buffer room. In the buffer room, there should be a wash sink, sterile clothes, slippers and wardrobe, etc., there should not be other debris placed. The wall of the sterile room should be smooth and smooth, and can withstand cleaning and disinfection. Discover more details at sz pharma.

In order to ensure the cleanliness of the air necessary in the clean room, to reduce or prevent indoor dust production and growth of microorganisms, reduce or prevent the introduction of particles, microorganisms or materials that may cause cross-contamination into the clean room, Pharma clean room facility effectively removing indoor particles / microorganisms discharge. In order to achieve the ideal purification effect and reduce the purification cost, local air purification equipment is often used, including pass box, clean bench, fume hood, weighing booth,laminar flow hood,etc.

Labeller is a device that pastes rolled self-adhesive paper labels (paper or metal foil) onto PCB, products or specified packaging. It has a wide range of applications, and can meet the full circle labeling or semi circle labeling of round bottles. The labeling switching between bottles is simple and easy to adjust. Blister packaging machine is a machine that uses transparent plastic film or sheet to form a blister and seals the product between the blister and the bottom plate by means of heat sealing and bonding. Application: capsule, plain tablet, sugar coating, capsule, injection, abnormity, etc., as well as sealed packaging of medical devices, light food, electronic components blister.

Efficiency of Equipment: Some equipment, such as electronics and mechanical components, require specific humidity levels to function correctly. Maintaining the right humidity levels in clean rooms ensures optimal performance and longevity of these critical pieces of equipment. How to Maintain Optimal Humidity Levels in Clean Rooms? To maintain optimal humidity levels in clean rooms, consider the following steps: Install a Dehumidifier: A dehumidifier is an essential tool for maintaining proper humidity levels in clean rooms. It removes excess moisture from the air, keeping humidity levels within the desired range. Choose a dehumidifier based on the size of your clean room and the relative humidity requirements you need to meet.

The plane and space design of the clean laboratory will arrange the clean experimental area and personnel purification, equipment and material purification and other auxiliary rooms in different areas. At the same time, the comprehensive coordination effects of various technical facilities, such as experimental operation, process equipment installation and maintenance, air distribution type, pipeline layout and purified air conditioning system, are considered.

For the unidirectional flow (laminar flow) clean room, the air supply volume is determined by the product of the average wind speed of the room section and the cross-sectional area, in which the measured section of the vertical unidirectional flow (laminar flow) clean room is the horizontal section 0.8m away from the ground; The horizontal unidirectional flow (laminar flow) clean room takes a vertical section 0.5m away from the air supply surface. The spacing of measuring points on the section shall not be greater than 2m, and the number of measuring points shall not be less than 10, which shall be evenly arranged. Hot bulb anemometer for instrument.

Airflow is the most important factor in controlling cleanliness and temperature and humidity, and it also has some influence on noise. Therefore, the wind speed measurement is the first step in the clean room test. The purpose of the wind speed measurement is to confirm that the air flow sent by the filter meets the design specifications, and the second is to confirm the uniformity of the air flow. In some occasions, due to site restrictions, the indoor ventilation volume must also be converted by multiplying the wind speed by the outlet area. Find additional information at https://www.sz-pharma.com/.

Clean room in pharmaceutical industry manufacturer right now: Obstacles such as work desks in the clean room will have eddy currents at the junctions, and the cleanliness will be relatively poor near them. Drilling air return holes on the work desks will minimize eddy currents; assembly Whether the selection of materials is appropriate and whether the equipment layout is perfect are also important factors for whether the airflow becomes a vortex phenomenon. The above introduction is related to clean room and airflow influencing factors.

The frame of the clean shed can be generally divided into three types: stainless steel square pass, varnished iron square pass and industrial aluminum profiles. The top and the top can be made of stainless steel steel plate, lacquered cold plastic steel plate, anti-static mesh curtain and acrylic plexiglass and other materials. Anti-static mesh curtains or plexiglass are generally used around, and FFU clean air supply units are used in the air supply unit.