Cleanroom pharma manufacturer and supplier today: The laboratory with multiple combinations can adopt single channel design, double channel design, and standard unit combination design. The structure of the laboratory should have applicability, versatility and flexibility to meet the needs of the subsequent development, renovation and expansion. Experimental rooms involving radioactivity, pollution and personal harm and other special requirements, the building layout, maintenance structure, decoration should meet the corresponding professional and technical requirements. The laboratory should be cleaned and disinfected regularly; ground, wall and ceiling shall be integral waterproof and dust-proof construction. The interior should reduce the protruding building fittings and open pipes; Between the wall and wall, the wall and ground, the wall and ceiling should be made of a radius of not less than 0.05m semi-rounded corner. See extra details at cleanroom pharma.
In order to ensure the cleanliness of the air necessary in the clean room, to reduce or prevent indoor dust production and growth of microorganisms, reduce or prevent the introduction of particles, microorganisms or materials that may cause cross-contamination into the clean room, Pharma clean room facility effectively removing indoor particles / microorganisms discharge. In order to achieve the ideal purification effect and reduce the purification cost, local air purification equipment is often used, including pass box, clean bench, fume hood, weighing booth,laminar flow hood,etc.
Labeller is a device that pastes rolled self-adhesive paper labels (paper or metal foil) onto PCB, products or specified packaging. It has a wide range of applications, and can meet the full circle labeling or semi circle labeling of round bottles. The labeling switching between bottles is simple and easy to adjust. Blister packaging machine is a machine that uses transparent plastic film or sheet to form a blister and seals the product between the blister and the bottom plate by means of heat sealing and bonding. Application: capsule, plain tablet, sugar coating, capsule, injection, abnormity, etc., as well as sealed packaging of medical devices, light food, electronic components blister.
Use a Hygrometer: A hygrometer is a device that measures the current humidity level in the room. By regularly monitoring the cleanroom humidity control with a hygrometer, you can identify any fluctuations and take corrective action if necessary. Ventilation: Proper ventilation is crucial for maintaining healthy humidity levels in clean rooms. Ensure that there are sufficient exhaust fans in place to remove excess moisture and carbon dioxide from the air. Additionally, consider installing temperature and humidity sensors to monitor changes in the environment and adjust ventilation accordingly. Control Water Sources: Closely monitor water sources within the clean room, such as sinks or taps, as they can contribute to high humidity levels. Be sure to turn off faucets when not in use and avoid running water unnecessarily.
Mainly control the pollution of air dust particles and organisms (bacteria) to working objects, and maintain a negative pressure with the atmosphere inside. Pharma cleanroom project It is suitable for precision machinery industry, electronics industry, aerospace industry, high-purity chemical industry, atomic energy industry, optomagnetic product industry, LCD, computer hard disk; pharmaceutical industry, hospital, operating room, sterile ward, food, cosmetics, beverage products Animal laboratory, physical and chemical laboratory, blood station, etc. More cases check our cleanroom project page.
The detection of air volume and wind speed must be carried out first, and all effects of purified air conditioning must be obtained under the designed air volume and wind speed. Before air volume detection, it is necessary to check whether the fan operates normally, whether all components in the system are installed correctly and whether there are obstacles (such as whether the filter is blocked or blocked). All valves should be fixed at a certain opening position, and the size of the measured air outlet and air duct must be measured. For the turbulent flow clean room, the air supply volume shall be determined by the air outlet method or air duct method. See Item 6, 7 and 8 respectively. For the air outlet without filter, the method in Appendix I of the current national standard code for construction and acceptance of ventilation and air conditioning engineering (gbj243) can be implemented.
Airflow is the most important factor in controlling cleanliness and temperature and humidity, and it also has some influence on noise. Therefore, the wind speed measurement is the first step in the clean room test. The purpose of the wind speed measurement is to confirm that the air flow sent by the filter meets the design specifications, and the second is to confirm the uniformity of the air flow. In some occasions, due to site restrictions, the indoor ventilation volume must also be converted by multiplying the wind speed by the outlet area. Read additional information at https://www.sz-pharma.com/.
Quality pharma clean room manufacturer and supplier: As long as you want the clean room project, Suzhou Pharma Machinery Co., Ltd. will realize it for you. Choose a reliable engineering company, Suzhou Pharma Machinery Co., Ltd., will be responsible for your project to the end, and the reputation is guaranteed. Our company has completed 500+ clean room projects all over the world. Many new and old customers like to buy the products they want in our company. The price is reasonable, the integrity is guaranteed, and the after-sales service is good.
The clean room is generally made of foam color steel or rock wool board with a vertical wall and an independent air-conditioning air supply system. The air is filtered through high-efficiency three-stage filtration in junior high schools. The personnel and materials are equipped with an air shower room and a transfer window for clean filtration.